cvsdist 2f7f4bd
#!/bin/bash
cvsdist 2f7f4bd
#
cvsdist 2f7f4bd
# named           This shell script takes care of starting and stopping
cvsdist 2f7f4bd
#                 named (BIND DNS server).
cvsdist 2f7f4bd
#
jvdias 3c357dd
# chkconfig: - 13 87
cvsdist 2f7f4bd
# description: named (BIND) is a Domain Name Server (DNS) \
cvsdist 2f7f4bd
# that is used to resolve host names to IP addresses.
cvsdist 2f7f4bd
# probe: true
cvsdist 2f7f4bd
cvsdist 2f7f4bd
# Source function library.
cvsdist 2f7f4bd
. /etc/rc.d/init.d/functions
cvsdist 2f7f4bd
cvsdist 2f7f4bd
# Source networking configuration.
cvsdist 4f506df
[ -r /etc/sysconfig/network ] && . /etc/sysconfig/network
cvsdist 2f7f4bd
cvsdist 2f7f4bd
# Check that networking is up.
jvdias e51c8f6
[ "${NETWORKING}" = "no" ] && exit 1
cvsdist aed7121
cvsdist 78e1f2e
[ -r /etc/sysconfig/named ] && . /etc/sysconfig/named
cvsdist 2f7f4bd
jvdias 38a73ea
[ -n "$ROOTDIR" ] && ROOTDIR=`echo $ROOTDIR | sed 's#//*#/#g;s#/$##'`
jvdias 38a73ea
jvdias e9f83df
RETVAL=0
jvdias e9f83df
named='named'
jvdias e9f83df
if [[ "$ENABLE_SDB" = [yY1]* ]] && [ -x /usr/sbin/named_sdb ]; then
jvdias e9f83df
    named='named_sdb';
jvdias e9f83df
fi;
jvdias e9f83df
prog=$named
jvdias e9f83df
jvdias e9f83df
[ -x /usr/sbin/$named ] || exit 1
cvsdist 2f7f4bd
jvdias 38a73ea
nmdcOption()
jvdias 38a73ea
{ let i=0; 
jvdias 38a73ea
  for a in $*; 
jvdias 38a73ea
  do ((++i)); 
jvdias 38a73ea
     if [ $a = -c ]; then 
jvdias 38a73ea
	 ((++i)); 
jvdias 38a73ea
	 eval 'echo $'$i;
jvdias 38a73ea
     elif [[ $a = -c* ]]; then 
jvdias 38a73ea
	 echo ${a#-c}; 
jvdias 38a73ea
     fi; 
jvdias 38a73ea
  done; 
jvdias 38a73ea
}
jvdias 38a73ea
named_conf=`nmdcOption $OPTIONS`;
jvdias 38a73ea
[ -r ${ROOTDIR}/${named_conf:-etc/named.conf} ] || exit 1
jvdias 4206716
cvsdist 2f7f4bd
start() {
cvsdist 2f7f4bd
        # Start daemons.
jvdias e9f83df
        echo -n $"Starting $named: "
jvdias e9f83df
	if [ -n "`/sbin/pidof -o %PPID $named`" ]; then
jvdias e9f83df
		echo -n $"$named: already running"
jvdias 6e144cb
		failure
jvdias 6e144cb
		echo
cvsdist 0a52a5f
		return 1
cvsdist 0a52a5f
	fi
jvdias b7b41ad
	ckcf_options='-z'; # enable named-checkzone for each zone (9.3.1+) !
cvsdist aed7121
	if [ -n "${ROOTDIR}" -a "x${ROOTDIR}" != "x/" ]; then
cvsdist aed7121
		OPTIONS="${OPTIONS} -t ${ROOTDIR}"
jvdias b7b41ad
		ckcf_options="$ckcf_options -t ${ROOTDIR}";
jvdias d3f5585
		if [ -s /etc/localtime ]; then
jvdias d3f5585
		    cp -fp /etc/localtime ${ROOTDIR}/etc/localtime
jvdias d3f5585
		fi;
jvdias 1abbaa0
		if [ ! -d ${ROOTDIR}/proc ]; then
jvdias 1abbaa0
		    mkdir -p ${ROOTDIR}/proc
jvdias 1abbaa0
		fi
jvdias f84fe39
		if ! egrep -q '^/proc[[:space:]]+'${ROOTDIR}'/proc' /proc/mounts; then
jvdias f4e1639
		    mount --bind /proc ${ROOTDIR}/proc >/dev/null 2>&1 
jvdias 1abbaa0
		fi
jvdias a06ea57
		dbus=0;
jvdias a06ea57
		for a in $OPTIONS; do
jvdias a06ea57
		    if [ $a  = "-D" ]; then
jvdias a06ea57
			dbus=1;
jvdias a06ea57
	            fi;
jvdias a06ea57
	        done
jvdias a06ea57
		if [ $dbus -eq 1 ]; then
jvdias dc8dced
		    if ! egrep -q '^/[^[:space:]]+[[:space:]]+'${ROOTDIR}'/var/run/dbus' /proc/mounts; then
jvdias f4e1639
			mkdir -p ${ROOTDIR}/var/run/dbus
jvdias f84fe39
			if [ ! -d  /var/run/dbus ] ; then
jvdias f84fe39
			    mkdir -p /var/run/dbus ;
jvdias f84fe39
			fi;
jvdias f84fe39
			mount --bind /var/run/dbus ${ROOTDIR}/var/run/dbus > /dev/null 2>&1;
jvdias f4e1639
		    fi;		    
jvdias a06ea57
		fi;		
cvsdist aed7121
	fi
jvdias 18d1e19
	no_write_master_zones=0
jvdias 23b1ff2
	if [ -e /etc/selinux/config ]; then
jvdias 23b1ff2
           .  /etc/selinux/config
jvdias b7b41ad
           if [[ ( "$SELINUX" != 'disabled') && ("$SELINUXTYPE" != "") && (-d /etc/selinux/${SELINUXTYPE}) && (-e /etc/selinux/${SELINUXTYPE}/booleans || (-e /etc/selinux/${SELINUXTYPE}/booleans.local)) ]]; then
jvdias b7b41ad
	       if [ -e /etc/selinux/${SELINUXTYPE}/booleans.local ]; then
jvdias b7b41ad
		   . /etc/selinux/${SELINUXTYPE}/booleans.local;
jvdias b7b41ad
	       else
jvdias b7b41ad
		   . /etc/selinux/${SELINUXTYPE}/booleans;
jvdias b7b41ad
               fi;
jvdias 2dbdf52
	       if echo "$named_write_master_zones" | /bin/egrep -q '^[0-9]+$'; then
jvdias 2dbdf52
		   if [ "$named_write_master_zones" -eq 1 ] ; then
jvdias 2dbdf52
		       /bin/chown -f --from=root:named named:named $ROOTDIR/var/named
jvdias 2dbdf52
		   elif [ "$named_write_master_zones" -eq 0 ] ; then
jvdias 2dbdf52
		       /bin/chown -f --from=named:named root:named $ROOTDIR/var/named
jvdias 2dbdf52
		   fi;
jvdias 2dbdf52
               fi;
jvdias 18d1e19
	   else
jvdias 18d1e19
	       no_write_master_zones=1
jvdias 23b1ff2
	   fi;
jvdias 18d1e19
	else
jvdias 18d1e19
	    no_write_master_zones=1
jvdias 23b1ff2
        fi;
jvdias 18d1e19
	if [ "$no_write_master_zones" -eq 1 ]; then
jvdias 18d1e19
	    if [[ "$ENABLE_ZONE_WRITE" =  [yY1]* ]]; then
jvdias 18d1e19
		/bin/chown -f --from=root:named named:named $ROOTDIR/var/named
jvdias 18d1e19
	    elif [[ "$ENABLE_ZONE_WRITE" =  [nN0]* ]]; then	        
jvdias 18d1e19
		/bin/chown -f --from=named:named root:named $ROOTDIR/var/named
jvdias 18d1e19
	    fi;
jvdias 18d1e19
	fi
cvsdist 49d83bc
        conf_ok=0;
jvdias 31ab244
	if [ -x /usr/sbin/named-checkconf ] && [ -x /usr/sbin/named-checkzone ] && /usr/sbin/named-checkconf $ckcf_options ${named_conf} >/dev/null 2>&1; then
cvsdist 49d83bc
           conf_ok=1;
cvsdist 49d83bc
        else
cvsdist 49d83bc
	   RETVAL=$?;
cvsdist 49d83bc
	fi
cvsdist 49d83bc
	if [ $conf_ok -eq 1 ]; then	   
jvdias e9f83df
	   daemon /usr/sbin/$named -u named ${OPTIONS};
cvsdist 49d83bc
	   RETVAL=$?;
jvdias b7b41ad
	   if [ $RETVAL -eq 0 ]; then
jvdias aad9089
	       rm -f /var/run/named.pid
jvdias e9f83df
	       rm -f /var/run/named_sdb.pid 2>/dev/null
jvdias b7b41ad
	       ln -s $ROOTDIR/var/run/named/named.pid /var/run/named.pid;
jvdias e9f83df
	       if [ "$named" = "named_sdb" ]; then
jvdias e9f83df
		   ln -s $ROOTDIR/var/run/named/named.pid /var/run/named_sdb.pid;
jvdias e9f83df
	       fi;
cvsdist 668aac5
	   fi;
jvdias b7b41ad
	else
jvdias 31ab244
	   named_err="`/usr/sbin/named-checkconf $ckcf_options $named_conf 2>&1`";	   
jvdias b7b41ad
	   echo
jvdias b7b41ad
	   echo $"Error in named configuration"':';
jvdias b7b41ad
	   echo "$named_err";
jvdias b7b41ad
	   failure
jvdias b7b41ad
	   echo
jvdias b7b41ad
	   if [ -x /usr/bin/logger ]; then
jvdias b7b41ad
	       echo "$named_err" | /usr/bin/logger -pdaemon.error -tnamed 
jvdias b7b41ad
           fi;
cvsdist 49d83bc
           return $RETVAL;
cvsdist 49d83bc
        fi;
cvsdist 78e1f2e
 	[ $RETVAL -eq 0 ] && touch /var/lock/subsys/named 
cvsdist 4f506df
        echo
cvsdist 2f7f4bd
	return $RETVAL
cvsdist 2f7f4bd
}
cvsdist 2f7f4bd
stop() {
cvsdist 2f7f4bd
        # Stop daemons.
jvdias e9f83df
        echo -n $"Stopping $named: "
jvdias aad9089
	/usr/sbin/rndc stop >/dev/null 2>&1 
cvsdist 2f7f4bd
	RETVAL=$?
jvdias b7b41ad
	if [ $RETVAL -eq 0 ]; then
jvdias b7b41ad
	    rm -f /var/lock/subsys/named
jvdias b7b41ad
	    rm -f /var/run/named.pid	    
jvdias e9f83df
	    rm -f /var/run/named_sdb.pid 2>/dev/null	    
jvdias e9f83df
	elif /sbin/pidof -o %PPID $named >/dev/null; then
jvdias e9f83df
	    killproc $named -TERM >/dev/null 2>&1
jvdias b7b41ad
	    RETVAL=$?
jvdias b7b41ad
	    if [ $RETVAL -eq 0 ]; then
jvdias b7b41ad
		rm -f /var/lock/subsys/named
jvdias b7b41ad
		rm -f /var/run/named.pid
jvdias e9f83df
		rm -f /var/run/named_sdb.pid 2>/dev/null	    
jvdias b7b41ad
	    fi;
jvdias b7b41ad
	fi;
jvdias b7b41ad
	if [ $RETVAL -eq 0 ]; then
jvdias b7b41ad
	    success
jvdias b7b41ad
	else
jvdias b7b41ad
	    failure
jvdias b7b41ad
        fi;
jvdias b7b41ad
	echo
cvsdist 2f7f4bd
	return $RETVAL
cvsdist 2f7f4bd
}
cvsdist 2f7f4bd
rhstatus() {
cvsdist 3664421
	/usr/sbin/rndc status
cvsdist 3664421
	return $?
cvsdist 2f7f4bd
}	
cvsdist 2f7f4bd
restart() {
cvsdist 2f7f4bd
	stop
cvsdist 78e1f2e
# wait a couple of seconds for the named to finish closing down
cvsdist 78e1f2e
	sleep 2
cvsdist 2f7f4bd
	start
cvsdist 2f7f4bd
}	
cvsdist 2f7f4bd
reload() {
jvdias e9f83df
        echo -n $"Reloading $named: "
jvdias e9f83df
	p=`/sbin/pidof -o %PPID $named`	
cvsdist d69ee3d
	RETVAL=$?
cvsdist d69ee3d
	if [ "$RETVAL" -eq 0 ]; then 
jvdias aad9089
	    /usr/sbin/rndc reload >/dev/null 2>&1 || /bin/kill -HUP $p;
cvsdist d69ee3d
	    RETVAL=$?
cvsdist d69ee3d
        fi
jvdias e9f83df
	[ "$RETVAL" -eq 0 ] && success $"$named reload" || failure $"$named reload"
cvsdist 78e1f2e
        echo
cvsdist 2f7f4bd
	return $?
cvsdist 2f7f4bd
}
cvsdist 2f7f4bd
probe() {
cvsdist 2f7f4bd
	# named knows how to reload intelligently; we don't want linuxconf
cvsdist 2f7f4bd
	# to offer to restart every time
cvsdist aed7121
	/usr/sbin/rndc reload >/dev/null 2>&1 || echo start
cvsdist 2f7f4bd
	return $?
jvdias b7b41ad
}
jvdias b7b41ad
checkconfig() {
jvdias b7b41ad
        ckcf_options='-z'; # enable named-checkzone for each zone (9.3.1+) !
jvdias b7b41ad
	if [ -n "${ROOTDIR}" -a "x${ROOTDIR}" != "x/" ]; then
jvdias b7b41ad
		OPTIONS="${OPTIONS} -t ${ROOTDIR}"
jvdias b7b41ad
		ckcf_options="$ckcf_options -t ${ROOTDIR}";  
jvdias b7b41ad
	fi;
jvdias 31ab244
	if [ -x /usr/sbin/named-checkconf ] && [ -x /usr/sbin/named-checkzone ] && /usr/sbin/named-checkconf $ckcf_options ${named_conf} | cat ; then
jvdias b7b41ad
	    return 0;
jvdias b7b41ad
	else
jvdias b7b41ad
	    return 1;
jvdias b7b41ad
	fi
jvdias b7b41ad
}
cvsdist 2f7f4bd
cvsdist 2f7f4bd
# See how we were called.
cvsdist 2f7f4bd
case "$1" in
cvsdist 2f7f4bd
	start)
cvsdist 2f7f4bd
		start
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	stop)
cvsdist 2f7f4bd
		stop
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	status)
cvsdist 2f7f4bd
		rhstatus
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	restart)
cvsdist 2f7f4bd
		restart
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	condrestart)
cvsdist 31bdca3
		if [ -e /var/lock/subsys/named ]; then restart; fi
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	reload)
cvsdist 2f7f4bd
		reload
cvsdist 2f7f4bd
		;;
cvsdist 2f7f4bd
	probe)
cvsdist 2f7f4bd
		probe
cvsdist 2f7f4bd
		;;
jvdias e9f83df
        checkconfig|configtest|check|test)
jvdias b7b41ad
	        checkconfig
jvdias b7b41ad
		;;
cvsdist 2f7f4bd
	*)
cvsdist aed7121
        	echo $"Usage: $0 {start|stop|status|restart|condrestart|reload|probe}"
cvsdist 2f7f4bd
		exit 1
cvsdist 2f7f4bd
esac
cvsdist 2f7f4bd
cvsdist 2f7f4bd
exit $?
cvsdist 2f7f4bd